  • LTCVENTILATION Centrifugal Double-Volute Direct-Drive Fans Enter the Market

    2026年10月9日

    Saudi  Metro  and  Building  Ventilation Upgrades: LTCVENTILATION  Centrifugal  Double-Volute Direct-Drive Fans Enter the Market Saudi Arabia is accelerating its rail expansion and building energy-effici...

  • Application of Ventilation Fan in Data Centre

    2026年3月12日

    Capable of operating in a temperature range of -30 ℃ to 46 ℃ or even higher; constant temperature and humidity Maintain relative humidity indoors and keep a constant temperature; Must remove dust; High automation requirements;...

  • How to do Maintenance to Marine Ventilation Fans

    2026年3月10日

    Marine fans are running on ships and exposed to high humidity and salt, oil contamination, and turbulent conditions. Maintenance is crucial for ensuring their readiness for use and extending service life. Daily check, periodic mainte...

  • Control Methods for Centrifugal EC Fan

    2026年2月26日

    Control Methods for Centrifugal EC Fan (Brushless Motor + Intelligent Control) Aim atApplicationControl PrecisionControlled byConstant SpeedStable Load★★★☆☆0-10V/PWM to set a constant rotation speedConstant Air FlowFilter System ...

  • Water Hammer Effect in Fan Coil Units

    2026年2月5日

    As a closed water circulation device for the terminal of central air conditioning, the water hammer effect in the fan coil unit (FCU) system belongs to a low-pressure, small-amplitude water hammer. Due to the system's low operating pres...

  • Annual Energy Saving of Centrifugal Fan EC500

    2026年2月4日

    1.     About Working State ItemValueRemarkBest working point1350W(input power)Q=5980m³/h,P=992Pa,η=90%Working time8760h per year24h continuously:24×365=8760hElectricity charge for industry0.65 yuan /kWh ...

  • EC Centrifugal Fan with Backward Curved Direct Drive

    2026年2月4日

    EC direct-drive centrifugal fan with backward blade is a high-efficiency ventilation device that is directly driven by an electronically commutated (EC) permanent magnet synchronous motor with a backward centrifugal impeller. It ...

  • Why should we install FCU in the way: bottom supply & top return (BS&TR)

    2026年2月2日

    Installation of FCU : bottom supply & top return (BS&TR) When doing the installation of fan coil units ( FCU ), water inlet and water outlet are usually arranged in the way that supply from below and return from above. That m...

  • Comparation between Mixing Ventilation and Displacement Ventilation

    2026年1月16日

    ItemMixing VentilationDisplacement VentilationGoalto achieve even room temperature and humiditycomfort in working zoneDriven byfluid dynamicsbuoyancyPrinciplestrong mixing of airflowdiffusion of airfow and lift of buoyanceWorking Charac...